Chart w/ Sample Drawings and Specs

PDI Sound Control Selector Chart

This chart provides sample product and technical data to assist in the proper selection of PDI's Acoustical Products.  More options are available, contact PDI technical staff.

Sliding Doors

Sonicbar Model Application Architectural Configuration Acoustical Rating Other Criteria (as required) Hardware Function & Type Sonicbar Seal & Sill Condition Anchorage Sample Drawing
DS4-50-FS Laboratory Horizontal sliding 50 STC Manual w/ pneumatic control Flush w/ Auto-air seals Special anchorage 2402-19 Sht. 1
DS4-50-FS College - Fine Arts Center Horizontal sliding 50 STC Power operated electro-pneumatic Flush w/ Auto-air seals Thru bolts on track 1631-06 Sht. 6

Swing Doors (Oversize)

Sonicbar Model Application Architectural Configuration Acoustical Rating Other Criteria (as required) Hardware Function & Type Sonicbar Seal & Sill Condition Anchorage Sample Drawing
DS4-46F Sound stage Large pair 46 STC Sonicbar SH Latchset H-214 seals Flush sill Cast-in 1824-09 Sht. 3
DS4-46F Sound stage Tri-fold 46 STC Sonicbar SH Latchset H-214 seals Flush sill Cast-in 1824-09 Shts. 2 & 8
DS4-52L Performing Arts Center Large Pair 52 STC Sonicbar SH Latchset H-214 seals Low sill Masonry anchors 1673-07 Sht. 1
DS4-52L Fine Arts Center Tri-fold 50 STC Sonicbar SH Latchset H-214 seals Low sill Weld-in 1631-06 Shts. 1 & 2

Engine Test Cell Doors (Single swing and pairs)

Sonicbar Model Application Architectural Configuration Acoustical Rating Other Criteria (as required) Hardware Function & Type Sonicbar Seal & Sill Condition Anchorage Sample Drawing
DS4-48F Transmission Test Cell Single 48 STC Blast & bullet resistant Sonicbar SH Latchset H-214 seals Flush sill Weld-in 1352-00 Sht. 1
DB-48L Engine Test Cell Facility Single 45 STC Blast resistant Sonicbar SH Latchset H-245 seals Low sill Masonry anchors 2264-17 Sht. 4
DB-10 / 40 STC Engine Test Cell Single 40 STC Blast & bullet resistant; 3-hr Fire Label Sonicbar SH Latchset H-280 seals Low sill Masonry anchors 1600-05 Sht. 1
DS4-50F Transmission Test Cell Pair 50 STC Blast Resistant Sonicbar SH Latchset H-214 seals Flush sill Weld-in 2065-13 Shts. 1, 5 & 2
DS4-50F Tech Center Test Cell Pair w/ split door at active 50 STC Sonicbar SH Latchset H-214 seals Flush sill Weld-in 1745-08 Sht. 1
DS4-50F Tech Center Test Cell Single 50 STC Sonicbar SH Latchset H-214 seals Flush sill Cast-in 1745-08 Sht. 4
DS4-52L / DB-10 Combo Aircraft Engine Test Cell Single 50 STC Blast resistant Sonicbar SH Latchset H-216 seals Low sill Cast-in 2104-14 Sht. 1
DS6-59L Airlines Engine Test Cell Single 59 STC Sonicbar SH Latchset H-216 seals, H-344 sill seal, gasket & threshold Masonry anchors 1473-02 Sht. 1
DS6-61L NAVFAC Engine Test Cell Single 59 STC Sonicbar SH Latchset H-216 seals Low sill Cast-in 2329-18 Sht. 1
DS6-61L AFB Jet Engine Test Cell Pair 61 STC Sonicbar SH Latchset H-216 seals Low sill Cast-in 1663-07 Sht. 3

Windows

Sonicbar Model Application Architectural Configuration Acoustical Rating Other Criteria (as required) Hardware Function & Type Sonicbar Seal & Sill Condition Anchorage Sample Drawing
WS Army base Engine Test Cell 53 STC Blast resistant Neoprene Cast-in 1155-96 Sht. 4
WS Power plant 52 STC Neoprene Steel stud anchors 2492-21 Sht. 1

Few notes:

PDI supplies the entire assembly:

▪ Swing door -- frame, anchorage, door panel, hinges, hardware, operator (if required) and adjustable sound seals

▪ Sliding door -- door panel, pull handles, track/trolley system (normally top-hung), door   binders, stay roller, floor stop, electro-pneumatic operation (as required) and air seals.

▪ Drawings are proprietary and provided for reference purposes only. PDI reserves the right to alter design details and/or product specifications at any time without notice.

▪ Drawings are also a general representation of the multitude of door and window systems PDI has designed and built, and not intended to be an exact representation of door

construction, hardware requirements, wall conditions or anchorage. PDI will make final determination on door model or construction after analyzing criteria and architectural details.

▪ Standard specifications are listed below. If WORD document is preferred, contact PDI.


Note: Specifications are not to be changed or altered. Please do not insert hollow metal door standards or builder's hardware. Special purpose doors are engineered to performance

criteria and have their own unique attributes.

Specification for Sound Control Swing Door

Specification for Sound Control Sliding Door

Share by: